Philips Onsite Adult Infant Child Training Replacement Electrode Pads M5094A | |||
................................................................................................................................................................................... | |||
. | |||
. | |||
. | |||
......|
Home
|
Onsite AED Training
Unit
| Philips
Cabinets
|
Onsite
AED Wall Signs
|
HeartStart Accessories
|
Contact Us
... |
|||
HeartStart Best Package
|
Emergency Oxygen|
Training
Manikins |
School Package .
|
View
Shopping Cart
... |
Associated Owner's Manuals and Training Accessories. Buy all now. Save time. Save shipping.▼ |
![]()
|
![]()
|
..Philips Heartstart OnSite Adult TRAINING Pad Cartridge M5073A is used to facilitate training on the OnSite Defibrillator M5066A. This special purpose pad, when installed in the HeartStart OnSite, suspend the defibrillator’s ability to deliver a shock and activate its training mode, enabling the user to run any of eight emergency scenarios. The defibrillator’s voice instructions, including cardiopulmonary resuscitation (CPR) coaching, will be appropriate for treating the simulated victim. OnSite Adult TRAINING Pad Cartridge consists of a removable clear protective lid with a handle, a re-sealable film cover, and a pair of reusable adhesive pads. It is packaged with a Adult Pads Placement Guide and illustrated instructions for installing the cartridge, using the Pads Placement Guide, and repackaging the cartridge after using it. A training pads cartridge can also be used on a manikin, connected with an internal (M5088A) or external (M5089A) manikin adapter. NOTE: If you carry an Adult Training Pads Cartridge Item #M5073A, it is recommended that you store it separately from the OnSite Defibrillation pads, so the training pads cannot be confused with the regular pads in an emergency. It is important that the patient pads and the Philips Heartstart Onsite AED Adult Training Pads Cartridge Item# M5073A packs are not be used past their expiration dates. * Replacement pads are available for the adult training cartridge: Part # M5093A |
Philips Onsite Adult PadsThe package contains one pair of adult defibrillation pads for use with the Philips Onsite AED. These pads are for adult use only (8 years or older). Pads should be stored connected to the defibrillator Extra pads can be stored in the available carrying case. Pad package has a two-year shelf life.The Philips Heartstart Onsite AED Defibrillator uses two self-adhesive defibrillation/monitoring pads to monitor ECG signals and, if necessary, to deliver defibrillation energy to the patient. These pads (also known as electrodes) are provided in a single-use, disposable package. Do not allow defibrillation pads to touch each other, or to touch other ECG electrodes, lead wires, dressings, transdermal patches, etc. Such contact can cause electrical arcing and patient skin burns during defibrillation and may divert defibrillating energy away from the heart. Replacing Pads The HeartStart Adult SMART Pads are intended for one time use only. The pads must be replaced after each use or if the package has been damaged. The Philips Heartstart Onsite AED Defibrillator Adult Replacement SMART Pads Cartridges, Item #M5071A are supplied in a sealed pouch with the connector. This allows the pads to be stored in a pre-connected state for rapid deployment during an emergency. Caution: DO NOT remove the extra set of stored defibrillation pads from the sealed package until the pads are to be used. The packaging should be opened only immediately prior to use, otherwise the pads may dry out and become non-functional. First, check to ensure that the pad package has not expired. Pads past their expiration date should not be used and should be discarded. Insert the connector end of the Onsite AED Defibrillator Adult Replacement SMART electrodes cable into the pads connector port. Press the pads connector in firmly until it is fully seated in the unit. Caution: The pads are intended for one time use only and must be discarded after use or if the package has been opened. Checking Pad Pack Expiration Dates: It is important that the patient pads and the battery packs not be used past their expiration dates. The expiration date of the pad package is printed on the outside of the sealed package. The expiration date of the battery pack is printed on the label on the pack. Always remove and replace by this date; when the battery pack is used up, the unit will indicate “low battery” or “replace battery” and will flash the Active Status Indicator red. Once an accessory is past its expiration date, it should be replaced immediately. Follow the instructions in the “Installing and Removing the Battery Pack” and “Connecting the Pads” sections to replace the part with an unexpired part. Patient pads should be discarded. Battery packs should be appropriately recycled.Associated Accessory. Buy both now, save time. Save shipping.▼
Children under 8 years of age or weighing less than
55 pounds (25 kg), including infants, should be
treated using HeartStart Infant/Child SMART Pads.
These pads instruct the defibrillator to reduce the
energy of its shock from 150 to 50 Joules (J), a
more appropriate dosage.1,2 . The Infant/Child Pads
cartridge is marked with an indication of patient
weight and with a teddy bear icon for easy
identification. Purchase of this product requires a
prescription.
|
....
Your One-Stop Source
for all Philips
Onsite Defibrillator Replacement Parts...Click
Here
AED ProfessionalsTM
General Medical Devices, Inc. Company
Corporate Office:
348
W. Colfax Street, Palatine IL 60067
Phone: 1-847-202-3858
Fax: 1-866-879-7795 Toll Free: 1-888-541-2337
Copyright © 2004 - 2010 All rights
of design and text reserved
AED
Professionals is AED and AED Accessories Wholesale and Retail Store
of Super Defibrillator Values
AED Professionalsè
Copy Righted: ©Quick-Start
Package
AED ProfessionalsèCopy
Righted: ©Quick-Start
Essentials
Package